Product Type: Medical X-ray Machine
Place of origin: China
Model No: YSX0104
Price Terms: FOB, CIF
Payment Terms: L/C, D/P, T/T
Package:
Minimum Order:
Delivery Time:
Brand Name:

125mA China Radiograhpy X Ray Machines YSX0104
USE
General radiography,Filter-ray device radiography
Unit Configuration
Control, HT generator unit, Ht cable, X-ray tube unit, Diagnostic table, Collimator
Main Characters
1. Single table and single tube
2. Design according to the electric mechanism of middle-size machine. The function of this photography x ray is reasonable.
3. High-tension system is of split structure, with high-voltage generator of full-wave rectification and stable operation
4. Supply voltage (V), photograph kilovolt (kv) and stepless adjust able
5. Equipped with the manostat for filament of X-ray tube and the spacecharge compensator as to ensure the stable and accurate output
6. Equipped with the capacity limitation and portection circuit and KV mA S interlock limitation and protection
7. The timer circuit grade according to R10 priority coefficient and an exact time control
8. The radiograph flat table has a vibrating ray-filter
9. The pillar hast has only the bottom track only, with easy installation
Min Technical Indexes
|
Supply power |
Voltage |
single phase 220V/380V±10% |
||
|
Frequency |
50Hz±0.5Hz |
|||
|
Capacity |
10KVA |
|||
|
Intemal resistance |
380v: 2Ω, 220V: 0.6Ω (2Ω at 80v; 06Ω at 220V) |
|||
|
Max DC output voltage |
90KV |
|||
|
Max DC output current |
125mA |
|||
|
Radiograph |
Voltage |
50-90KV |
||
|
current |
Small focus 15mA, big focus 30mA 60mA 100mA 125mA |
|||
|
spot film |
100mA(fixed) |
|||
|
time |
0.04-6.3s, 24grades together |
|||
|
High-voltage generator |
Capacity |
7KVA |
||
|
X-Ray tube |
Model |
XD4-2.9/100 |
||
|
Focus |
Small focus 1.8mm big focus4.3mm |
|||
|
Radiograph table |
Bed face(L×W×H) |
1960×660mm×700mm |
||
|
Bucky |
Grid density N28 |
|||
|
Convergence distance fo 100cm |
||||
|
Grid ratio |
||||
|
Max size of cassette |
356mm×432mm(14″×17″) |
|||
|
Pollar of X-ray source unit |
Moving in length (along The bottom table ) |
﹥1350mm |
||
|
moving un breath |
﹥360mm |
|||
|
moving up and down |
720~1800mm |
|||
|
MAX VOLUME OF RADIOGRAPH |
||||
|
Focus of X-Ray tube |
Radiograph mA |
Max Radiograph KV |
Max exposure time allow |
|
|
Small focus |
15mA |
90KV |
6.3S |
|
|
Large focus |
30mA |
90KV |
6.3S |
|
|
60mA |
90KV |
6.3S |
||
|
100mA |
85KV |
2.5S |
||
|
125mA |
82 KV |
1.0S |
||