500mA Medical X-Ray Photography Machine YSX0117

Product Type: Medical X-ray Machine

Place of origin: China

Model No: YSX0117

Price Terms: FOB, CIF

Payment Terms: L/C, D/P, T/T

Package:

Minimum Order:

Delivery Time:

Brand Name:

Products Informatin

500mA Medical X-Ray Photography Machine YSX0117
500mA Medical X-Ray Photography Machine YSX0117

1) Single diagnostic table with single x-ray tube configuration,125kV and 100kV can be selected.
2) This medical x ray machine is single phased bridge-type full wave and high voltage commutation.
3) In order for the X-ray tube to be used safely for a long period of time, multi-layer protection are utilized, these include :x-ray tube capacity protection, fluoroscopy time accumulation devices protection and x-ray tube overheating protection.
4) According to the type and degree of protection against electric shock. The machine is a type I and model B equipment. The x-ray tube assembly can protect against electric shocks and is radiation leak proof, it works safely and dependably.
5) Diagnostic table has protection against radiation and diffusion to ensure the safety of operators and examines.
6) The design is intended for small to medium hospitals to be used in conjunction with spot film radiography, bucky radiography and common radiography.

Department Technology parameters
High voltage generator Radiography Tube currency 100-500mA shift
Tube voltage 45-125KV continuous voltage
Exposure time 0.02-5s, 23 shift
 Power Voltage 380V±10%
Frequency 50Hz±1Hz
Capacity ≥30KVA
Inner resistance 380V:≤1.0Ω;220V: ≤0.3Ω
X-ray assembly Type of x-ray XD51-20.40/125
 Focus 1×1.2×2 double focal
Rated rotate speed of anode 2800r/min
Changed beam limited device Radiograph table YS11S Manually adjusted field of view, luminosity≥100LX
CDG
Multi function radiography table
Moving table Lengthways ±600mm Manually Electromagnetism locking
Across ±120mm
Mobile beam filtration grid Grid density 28L/cm
Grid ratio 8:1
Focusing distance 100cm
Scope of moving ≥640mm
Radiography item 5"×7",  8"×10",  10"×12",  11"×14", 
12"×15',  14"×14",  14"×17"
Distance from surface to film 75mm
Height of bed 700mm
Moving pillar ±180°,  per 90°orientation, moving lengthways ≥1500mm
Bulb tube Rotate the cross arm±180,  ascend $ descend 1100mm
Pillar Scope of bulb tube Ascend $ descend 300mm-1800mm
Moving crossover 780mm
Moving lengthways 3000mm
Rotation of bulb tube Moving pillar ±1800,  per 900 orientation,   shift
High of pillar 2750mm~3150mm

Option
LSJ pillar radiography frame The scope of ascend and descend 1450mm
The minimum distance from focal spot 380mm
Radiography item 5"×7",   8"×10",  10"×12",  11"×14", 
12"×15",   14"×14",   14"×17"
Fixed beam filtration role Grid density 40L/cm
Grid radio  10:1
Focal distance 180cm